PICurv 0.1.0
A Parallel Particle-In-Cell Solver for Curvilinear LES
 
Loading...
Searching...
No Matches
f3472887-run-diagnostics
  • Run diagnostics for locating and stopping a failing solve (f3472887; #24, #25, #26, #28, #29):
    • wall_model.csv records the wall face and cell of the maximum friction velocity and y+.
    • inlet_flow.csv adds fluctuation_flow_rate and applied_flow_rate, the flux an inlet with synthetic fluctuations actually admits; flow_rate remains the rescaled mean.
    • New boundary_pressure.csv: per-step mean pressure on each inlet and outlet face, whose difference is the pressure drop.
    • New solver.yml key tolerances.max_consecutive_unconverged_steps stops a run after that many consecutive unconverged momentum steps (default 0, off).
    • picurv run gives the one-rank restart-continuation check 120 s and undoes staging with a named cause instead of hanging on a cluster login node.